| Category
|
|
Power & Rack Equipment
|
|
Rack Equipment
|
APC
|
NetShelter
|
Power Distribution
|
| Buy Price GST Ex
|
Buy Price GST Inc
|
|
$1,607.27
|
$1,768.00
|
| Stock
|
GST Rate
|
|
24
|
10%
|
| Description
|
APC Rack PDU, Switched, 1U, 16A, 208/230V, (8) C13
Switched Rack Power Distribution Units (PDUs) provide advanced load monitoring combined with remote on/off switching control of individual outlets for power cycling...
Includes: Installation Guide, Rack Mounting Brackets, User Manual
|
| Detailed Description
|
AP7921B Features
Rack PDU, Switched, 1U, 16A, 208/230V, (8)C13
Switched Rack Power Distribution Units (PDUs)
provide advanced load monitoring combined with
remote on/off switching control of individual
outlets for power cycling, delayed power
sequencing, and outlet use management.
Includes: Installation Guide, Rack Mounting
Brackets, User Manual
Switched Rack PDU Features &
Benefits
Remote Individual Outlet Control
Remotely manage outlets so users can turn
outlets off that are not in use (prevent
overloads) or recycle power to locked-up
equipment (minimize costly downtime and
avoid travel time to equipment).
Flash Upgradeable
Quickly and easily upgrade firmware via
network download for future product
enhancements. Eliminates the need to replace
products already installed in the field when
new features are released. (Note: Networked
units only)
Local Current Monitoring Display
The aggregate current draw per rack PDU is
displayed on the unit via a digital display.
The local digital display helps installers
avoid overloaded circuits by providing a
visible warning when the current draw is
close to the maximum amperage draw of the
strip. (Available on designated SKUs only)
Network port sharing
Allows four rack PDUs to be connected using
In and Out ports so that only one network
connection is necessary.
Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring
system that collects, organizes, and
distributes critical alerts, surveillance
video and key information, providing a
unified view of complex physical
infrastructure environments from anywhere on
the network
Network Management Capabilities
Full-featured network management interfaces
that provide standards-based management via
Web, SNMP, and Telnet. Allows users to
access, configure, and manage rack PDUs from
remote locations to save valuable time.
Associated with this feature is the ability
to quickly and easily upgrade the firmware
via network download to installed units for
future product enhancements.
Power Delays
Allows users to configure the sequence in
which power is turned on or off for each
outlet. This helps avoid in-rushes at
start-up, which can cause overloaded
circuits and dropped loads. Sequencing also
allows users to predetermine which piece of
equipment is turned on first so other
equipment dependant on that unit will
function properly.
Alarm Thresholds
Define alarm thresholds in order to avoid
overloaded circuits. Network and visual
alarms inform the user of possible problems.
(Note: Only available on units with the
current monitoring capabilities. Please see
SKU specifications for availability)
Multi-tier user access
Supports up to four access levels -
Administrator, Device User, Read-Only User
and Network-only User - with user name and
password requirements.
Single input power source
Supply power from one branch whip to
multiple pieces of equipment, conveniently
powering rack-mount equipment. Saves time
and money during installation by using one
branch whip and standard connections.
Wide range of input and output connections
Product family includes a variety of input
and output connections to distribute 120V,
208V, or 230V power to multiple outlets.
Having a variety of inputs and outputs allow
users to adapt to varying power
requirements. APC offers units that bring up
to 14.4kW using a single branch whip.
Rack-Mountable
Includes horizontal, vertical, and
toolless-mount varieties. Puts power where
it is needed most - in the racks near the
equipment.
Power Delays
Allows users to configure the sequence in
which power is turned on or off for each
outlet. This helps avoid in-rushes at
start-up, which can cause overloaded
circuits and dropped loads. Sequencing also
allows users to predetermine which piece of
equipment is turned on first so other
equipment dependant on that unit will
function properly.
Alarm Thresholds
Define alarm thresholds in order to avoid
overloaded circuits. Network and visual
alarms inform the user of possible problems.
Remote Management Capabilities
Full-featured network management interfaces
that provide standards-based management via
Web, SNMP, and Telnet. Allows users to
access, configure, and manage units from
remote locations to save valuable time.
Associated with this feature is the ability
to quickly and easily upgrade the firmware
via network download to installed units for
future product enhancements.
Remote Individual Outlet Control
Remotely manage outlets so users can turn
outlets off that are not in use (prevent
overloads) or recycle power to locked-up
equipment (minimize costly downtime and
avoid travel time to equipment).
Local Current Monitoring Display
The aggregate current draw per power
distribution unit is displayed on the unit
via a digital display. The local digital
display helps installers avoid overloaded
circuits by providing a visible warning when
the current draw is close to the maximum
amperage draw of the strip.
|
Maximum Total Current Draw
Output Connections
(8) IEC 320 C13 (Battery Backup)
Regulatory Derated Input Current (North America)
Operating Relative Humidity
Storage Relative Humidity
Approvals
cUL Listed, CE, CSA, EN 55022 Class A, EN
55024, EN 61000-3-2, EN 61000-3-3, GOST,
IRAM, MIC, UL 60950, UL Listed, VDE, VCCI
Standard warranty
2 years repair or replace
Proposition 65 Warning
Available in Documentation tab
|
| Warranty Details
|
Warranty Period :
2